Programmable Thermal Shock Chamber
Description:
Corresponding standard:
The programmable thermal shock chamber is used to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment, which is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm.
It can be used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time, Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is high-temperature region, another is low-temperature region, the testing sample placed on the moving basket, using unique heat storage and cool storage,the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing; applied to test the material, including metal, plastic, rubber, electronics ....and other materials, it can be used as a basis for improvement of their products.
Name | Thermal Shock Test Chamber | ||
Mode | TS-49(A~C) | TS-80(A~C) | TS-150(A~C) |
Internal Dimension WxHxD (mm) | 400x350x350 | 500x400x400 | 600x500x500 |
External Dimension WxHxD (mm) | 1400x1800x1400 | 1550x1950x1550 | 1600x2000x1700 |
Temperature Range of Testing zone |
Type A:-40 ºC~+150ºC ( 200ºC is Optional) | Type B:-55ºC ~+150ºC ( 200ºC is Optional ) | Type C:-65ºC ~+150ºC ( 200ºC is Optional) |
Control Accuracy / Distribution Uniformity | ±0.5ºC/±2ºC | ||
Internal and External Material | Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or see cold-rolled steel with paint coated. | ||
Insulation Material | High temperature resistant , high density , formate chlorine , ethyl acetum foam insulation materials |
Corresponding standard:
- GB/T2423.1-1989 low-temperature testing method
- GB/T2423.2-1989 high-temperature testing method
- GB/T2423.22-1989 change temperature test
- GJB150.5-86 temperature impact test
- GJB360.7-87 temperature impact test
- GJB367.2-87 405 temperature impact test
Features:
- It is divided into three zones: high temperature zone, low temperature zone, and testing zone. The test sample is in static mode.
- Using touch-control graph control as operation interface, easy to operate.
- Applying wind route conversation to the shock method to distribute temperature to the testing zone for cold and thermal shock measurement.
- For high temperature shock or low temperature shock, max. time is up to 999H, and max. circulation cycles are 9999 times.
- The system can be used for automatic Circulation Shock or manual selective shock.
- Adopt binary cooling system, with quick cooling effect. Cooling method is water cooling.
- Can entering normal temperature. RS-232 and RS-485 communication.